Liberty version 2.11.0 (build 4923) Release notes

This update resets decomodel and stack time!

New features

Changes

Error corrections

Bailout CCR mode

This mode is intended for use Liberty as bailout CCR device, with another CCR
used as main device.
In this mode the oxygen is not injected, only the loop volume is adjusted
by ADV. Decompression model is updated, where ppO2 equal SP is expected.
Diluent from the other device must be configured as "2nd device diluent".
When fraction O2 in the loop drops below O2 fraction in diluent (i.e. the diver
probably breathes from this device), the standard CCR mode is selected automaticaly.

Bailout GF handling

GF handling bound with mode change is now smarter.
Mode change CCR -> OC, Bailout GF is selected
Mode change OC -> CCR, Standard GF is selected
GF manually switched to Bailout GF remains active until manually switched to Standard GF.

Prebreathe timer

Setup / Preferences / Timeouts / Prebreathe time [min], default 5 min
If set nonzero, timer starts count down as a last step in dive check list.
This feature is independent whether check list is enabled or not.

Multiple users

Feature must be enabled and multiuser capable HS used (licence for HS needed and bootloader version at least 3.10.0)
Left handset stores the profile of the user

ppO2 from He

If all chemical sensors fail in dive mode, an alarm "pO2 measuring lost" is raised.
If the diluent contains at least 20% He, it is possible to switch the pO2 source to He measuring.
Setup / Faulty sensors / pO2 source, options "O2" or "He".
Automatic switch is no longer suppoorted.
When the He source is selected, all pO2 fields on handset screens have blue background and "pO2 indirect" message is on the base screen.
The pO2 indirect field on the technical screen (with sensors) has always blue background, as it shows "pO2 from He" everytime.
The %He field on the technical screen become dashed for both sensors, as %He calculation is invalid in this mode.

Emergency O2 injection

If all chemical sensors are not valid (error, disabled etc.), the depth is < 6m/20ft and the pO2 source is O2 sensors,
an emergency O2 injection + alarm is done every 6s. In fact, Liberty become an oxygen rebreather (6m / 20ft depth is safe for pure oxygen).
This action happens also in Surface mode.


Liberty version 2.10.0 Release notes

This version was not officially released, all changes are made public in next version.


Liberty version 2.9.0 (build 4165) Release notes

New features

Changes

Error corrections

Dive time termination

Setup / Preferences / Timeouts / Dive Time

Warning: Dive termination setting remains active, if not set to zero.


Liberty version 2.8.2 (build 4097) Release notes

New features


Liberty version 2.8.1 (build 3961) Release notes

New features


Liberty version 2.8.0 (build 3890) Release notes

This version resets configuration to factory defaults!

New features

Changes

Error corrections

TTS screen details

Items to configure:

During dive, TTS screen shows several new values:


Liberty version 2.7.0 (build 3692) Release notes

New features

Changes

Error corrections


Liberty version 2.6 (build 3653) Release notes

New features

Changes

Error corrections